Stainless Steel Wire Mesh Screen Sizes Chart: Mesh, Micron & Opening

Partly unrolled roll of woven stainless steel wire mesh screen on a workshop bench, with the square openings in sharp close-up

A stainless steel wire mesh size is defined by two numbers: the mesh count (openings per linear inch) and the wire diameter. Together they set the opening and the open area. For example, 16 mesh with 0.018 in wire has a 0.0445 in (1.13 mm) opening and about 51% open area, while 100 mesh with 0.0045 in wire has a 0.0055 in (140 µm) opening and about 30% open area. The chart below covers common sizes from 2 to 635 mesh in inches, millimetres and microns. After it you’ll find the formulas for any other size, a sieve-number table, calculated weights and the mesh to start with for common jobs.

Quick answers

  • Mesh count: mesh is the number of openings per linear inch, not per square inch, so 10 mesh has 10 openings in each inch of length.
  • Opening formula: the opening equals 1 ÷ mesh count minus the wire diameter, with everything in inches.
  • Open area formula: open area equals (opening × mesh count)² × 100, which is the percentage of the screen that is holes.
  • Same mesh, different opening: a thicker wire makes the opening smaller at the same mesh count, so always specify both numbers.
  • Mesh to microns: common matches are 100 mesh at about 140–150 µm, 200 mesh at about 75 µm, 325 mesh at about 45 µm and 400 mesh at about 38 µm.
  • Grade: the chart applies to any grade, because 304 and 316 mesh of the same count and wire have the same opening.

Stainless steel wire mesh size chart (2 to 635 mesh)

These are common plain- and twill-woven sizes with square openings. Opening and open area are calculated from the mesh count and wire diameter, so they are nominal figures. Suppliers stock different wire diameters at the same count, and woven cloth has manufacturing tolerances, so confirm the numbers with your supplier if the opening is critical.

Mesh (per inch) Wire (in) Wire (mm) Opening (in) Opening (mm) Opening (µm) Open area
2 0.063 1.60 0.437 11.10 11,100 76%
3 0.047 1.19 0.286 7.27 7,270 74%
4 0.047 1.19 0.203 5.16 5,160 66%
4 0.063 1.60 0.187 4.75 4,750 56%
5 0.041 1.04 0.159 4.04 4,040 63%
6 0.035 0.89 0.132 3.34 3,340 62%
8 0.028 0.71 0.0970 2.46 2,460 60%
8 0.035 0.89 0.0900 2.29 2,290 52%
10 0.025 0.64 0.0750 1.91 1,910 56%
12 0.023 0.58 0.0603 1.53 1,530 52%
14 0.020 0.51 0.0514 1.31 1,310 52%
16 0.018 0.46 0.0445 1.13 1,130 51%
18 0.011 0.28 0.0446 1.13 1,130 64%
18 0.017 0.43 0.0386 0.98 979 48%
20 0.016 0.41 0.0340 0.86 864 46%
24 0.014 0.36 0.0277 0.70 703 44%
30 0.012 0.30 0.0213 0.54 542 41%
40 0.010 0.25 0.0150 0.38 381 36%
50 0.009 0.23 0.0110 0.28 279 30%
60 0.0075 0.19 0.0092 0.23 233 30%
70 0.0065 0.17 0.0078 0.20 198 30%
80 0.0055 0.14 0.0070 0.18 178 31%
100 0.0045 0.11 0.0055 0.14 140 30%
120 0.0037 0.094 0.0046 0.12 118 31%
150 0.0026 0.066 0.0041 0.10 103 37%
180 0.0023 0.058 0.0033 0.083 83 34%
200 0.0021 0.053 0.0029 0.074 74 34%
250 0.0016 0.041 0.0024 0.061 61 36%
325 0.0014 0.036 0.0017 0.043 43 30%
400 0.001 0.025 0.0015 0.038 38 36%
500 0.001 0.025 0.0010 0.025 25 25%
635 0.0008 0.020 0.0008 0.020 20 24%

Three counts appear twice to show how much the wire matters. 18 mesh in 0.011 in wire has about 64% open area, while 0.017 in wire drops that to about 48% and makes a much stiffer cloth. For window screen sizes such as 18×16 and the “¼ inch” and “⅛ inch” names used for hardware cloth, see the stainless steel mesh screen guide.

Three samples of woven stainless steel wire mesh side by side, from a coarse mesh with large openings to a very fine mesh that looks like cloth
As the mesh count rises, the wire gets thinner and the openings get smaller.

How to read the chart

Column What it means Why it matters
Mesh count Openings per linear inch, counted from the centre of one wire to a point one inch away Sets the wire spacing (the pitch). It does not tell you the opening on its own
Wire diameter Thickness of each wire, usually in decimal inches or mm Thicker wire gives a stronger, stiffer screen, but a smaller opening and less flow
Opening (aperture) The clear gap between two neighbouring wires Decides what passes through and what is stopped
Open area Percentage of the total screen area that is holes Higher open area means more airflow, light and liquid flow

The opening is the gap between the wires. The distance from the centre of one wire to the centre of the next is the pitch, and it is always larger than the opening by one wire diameter. Mixing the two up is the most common mistake when ordering mesh. A higher mesh count also doesn’t automatically mean a stronger screen: fine mesh uses thin wire, so it is usually the more delicate of the two. For strength, compare wire diameters.

How to calculate the opening for any mesh size

If your size isn’t in the chart, you can work it out from three short formulas.

You want Inch formula Metric formula (mm)
Pitch 1 ÷ M 25.4 ÷ M
Opening (1 ÷ M) − d (25.4 ÷ M) − d
Open area (opening × M)² × 100 (opening ÷ pitch)² × 100
Mesh count from opening and wire 1 ÷ (opening + d) 25.4 ÷ (opening + d)

M is the mesh count and d is the wire diameter. Here are three worked examples:

  • 5 mesh with 1 mm wire: the pitch is 25.4 ÷ 5 = 5.08 mm, so the opening is 5.08 − 1 = 4.08 mm. Open area is (4.08 ÷ 5.08)² × 100, or about 65%.
  • 40 mesh with 0.010 in wire: the opening is 0.025 − 0.010 = 0.015 in (0.38 mm). Open area is (0.015 × 40)² × 100 = 36%.
  • Metric cloth with a 1 mm opening and 0.5 mm wire: the pitch is 1.5 mm, which is 25.4 ÷ 1.5, or about 17 mesh. Open area is (1 ÷ 1.5)² × 100, or about 44%.

Metric mesh is often sold by opening and wire size rather than by count, so a listing like “1 × 1 mm” or “4 mm mesh” could mean either the opening or the pitch. Ask which one it is before you buy. Check too whether the openings are square: a size such as 18×16 has different counts in each direction, so its opening differs in each direction as well.

Mesh number vs micron: US test sieve sizes

Test sieves follow a fixed series, set out in ASTM E11 in the US and ISO 3310-1 internationally. A sieve number isn’t quite the same thing as a mesh count. A No. 100 sieve has a 150 µm opening, while the 100 mesh cloth in the chart above has a 140 µm opening. For rough conversions the difference rarely matters, but for particle-size work you should specify the sieve standard. The inch values are rounded.

US sieve No. Opening in US sieve No. Opening in
4 4.75 mm 0.187 45 355 µm 0.0140
5 4.00 mm 0.157 50 300 µm 0.0118
6 3.35 mm 0.132 60 250 µm 0.0098
7 2.80 mm 0.110 70 212 µm 0.0083
8 2.36 mm 0.093 80 180 µm 0.0071
10 2.00 mm 0.079 100 150 µm 0.0059
12 1.70 mm 0.067 120 125 µm 0.0049
14 1.40 mm 0.055 140 106 µm 0.0042
16 1.18 mm 0.046 170 90 µm 0.0035
18 1.00 mm 0.039 200 75 µm 0.0030
20 850 µm 0.0335 230 63 µm 0.0025
25 710 µm 0.0280 270 53 µm 0.0021
30 600 µm 0.0236 325 45 µm 0.0018
35 500 µm 0.0197 400 38 µm 0.0015
40 425 µm 0.0167

Other numbering systems also exist. Tyler mesh numbers match US sieve numbers at some sizes and differ at others, so a US No. 16 sieve (1.18 mm) corresponds to Tyler 14 mesh. When a specification only says “mesh”, ask for the opening in mm or µm. Industrial cloth has its own standards, ASTM E2016 and ISO 9044, so cloth bought off a roll is not automatically equivalent to a certified test sieve.

Which mesh size to use

These are typical starting points, not requirements. Equipment makers often specify a size for their own filters, and their figure should come first.

Job Typical mesh Note
Guards, coarse screening, hardware cloth 2–8 Choose heavier wire where the screen takes knocks
Rodent proofing 4 or finer About ¼ in openings at most, in heavy wire
Window and door insect screen 18×16 or 18×14 Thin wire keeps airflow high. Very small biting midges need about 20×20 or finer
Vents and soffits 8–18 Finer mesh blocks more insects, but reduces airflow and clogs sooner
Kitchen sieves and flour sifting 20–60 Finer sieves drain and sift more slowly
Tea infusers and strainers About 40–100 Go to the finer end for small-leaf tea
Reusable coffee and cold-brew filters About 100–300 Finer mesh leaves less sediment but flows more slowly
Pipeline strainers 20–100 Pick the coarsest size that protects the equipment downstream
Hydraulic suction strainers About 100 Follow the pump maker’s specification
Drip irrigation filters About 120–200 Follow the emitter maker’s specification
Fine powders and particle analysis 200–635 Use certified test sieves when results have to be traceable

To check your choice, compare the opening with the size of what you want to stop. Coarse sizes make this easy, but finer work needs care. A human hair is roughly 50–100 µm across and fine sand is about 125–250 µm, so 200 mesh (74 µm) stops fine sand. Mesh won’t stop fine dust or smoke, though. Particles around 2.5 µm are far smaller than even a 635 mesh opening (20 µm), so mesh can keep out coarse dust while passing air but is no replacement for a rated air filter.

A square opening also lets long, thin particles slip through end-on, and the diagonal of a square opening is about 1.4 times its width. If a filter must hold back a stated particle size, ask for a micron-rated filter cloth. Dutch weaves are the usual choice for this, because they have no simple square opening and are rated in microns rather than mesh.

How to measure mesh you already have

  1. Count the openings. Lay a ruler on the mesh and count the openings in one inch. For fine mesh, count across a measured 1 cm with a magnifier and multiply by 2.54.
  2. Count both directions. If the numbers differ, the mesh is rectangular, like 18×16 window screen.
  3. Measure the wire. Use a digital caliper or a micrometer on a single wire near an edge. Very thin wire is hard to measure without squashing it, so a micrometer gives a better reading.
  4. Calculate. Use the formulas above to get the opening and open area, then compare them with the chart.

Wire gauge numbers aren’t a reliable way to describe mesh wire, because different gauge systems give different diameters for the same number. Quote decimal inches or mm. The stainless steel wire guide has a decimal size table, and the gauge chart covers sheet, which uses a separate set of gauge numbers again.

Weight of stainless steel wire mesh

You can estimate weight from the mesh count and wire diameter. For 304 or 316 at a density of about 0.29 lb/in³ (8.0 g/cm³):

  • In inches: lb/ft² ≈ 65.6 × M × d²
  • In millimetres: kg/m² ≈ 0.495 × M × d²
Mesh × wire Approx. lb/ft² Approx. kg/m²
4 × 0.047 in 0.58 2.83
8 × 0.028 in 0.41 2.01
12 × 0.023 in 0.42 2.03
16 × 0.018 in 0.34 1.66
18 × 0.011 in 0.14 0.70
20 × 0.016 in 0.34 1.64
30 × 0.012 in 0.28 1.38
40 × 0.010 in 0.26 1.28
60 × 0.0075 in 0.22 1.08
100 × 0.0045 in 0.13 0.65
200 × 0.0021 in 0.06 0.28
325 × 0.0014 in 0.04 0.20

These figures are calculated from straight wire. Real woven wire follows a wavy path, so actual cloth weighs a little more. Use a supplier’s figure when weight matters for shipping or structural work.

Choosing the grade

The grade doesn’t change any dimension in the chart, but it does decide how long the mesh lasts. Thin wire has very little metal to lose, so a small pit that wouldn’t matter in thick sheet can break a strand.

Grade Use it for Watch out for
304 / 304L ✅ General use: indoor and inland outdoor screens, kitchen strainers, sieves ⚠️ Salt air, pools and de-icing salts can cause pitting and rust spots
316 / 316L ✅ Coastal sites, pool enclosures, chemical and pharmaceutical filtration ⚠️ Costs more, and isn’t immune in warm, strong chloride solutions
310 / 310S ✅ High-temperature screens and furnace belts ⚠️ Strength still falls as temperature rises
430 ✅ Dry indoor use and jobs that need a magnetic mesh ❌ Not a good choice for wet or outdoor use

The grades guide and 304 vs 316 comparison explain the differences in more depth. If the mesh will be welded, 316L and 304L are the low-carbon options. For hot service, remember that fine wire oxidises through far sooner than thick plate of the same grade, and that heat always reduces strength. Published scaling limits for bulk metal don’t tell you how long a thin screen will last.

How to specify mesh when you order

A clear order avoids most of the problems. Give the supplier:

  1. Mesh count in each direction, such as 16 × 16.
  2. Wire diameter, such as 0.018 in. Add a required opening if the opening is what really matters.
  3. Grade, such as 304 or 316L, with a material certificate if you need one.
  4. Weave, usually plain or twill for fine cloth, or crimped for heavy wire.
  5. Size, as roll width and length or cut pieces. Woven mesh is commonly sold in rolls around 36–48 in wide, and larger sizes are made to order.

A complete line reads: “16 × 16 mesh, 0.018 in wire, 304 stainless, plain weave, 36 in × 10 ft.” The cost depends mainly on the grade, the amount of metal in the wire and the fineness of the weave, with very fine cloth costing more to make. If you don’t need a woven cloth, stainless expanded metal or perforated stainless sheet may be stiffer alternatives for guards and panels.

Keeping mesh clean and rust-free

Blocked mesh effectively has a smaller open area, so cleaning restores flow as well as appearance. Wash it with warm water, mild detergent and a soft nylon brush, working along the weave, then rinse and dry it. The stainless steel cleaning guide covers stubborn deposits. Avoid carbon-steel wool and steel brushes, because they leave iron particles that rust on the surface. Avoid chlorine bleach as well: chlorine can cause pitting, and it will shorten the life of fine wire.

Don’t paint or zinc-coat stainless mesh to protect it. Coating closes up the openings, and zinc can harm stainless steel during later welding or heat. If you see orange spots, the stainless steel rust guide explains the likely cause and how to remove it. Where mesh is fixed to a frame, use stainless fasteners so a plated screw doesn’t become the first thing to rust.

Products mentioned in this guide

Links go to Amazon so you can compare current options, prices and reviews.

As an Amazon Associate, SheetStainlessSteel.com earns from qualifying purchases. This doesn't change our recommendations or your price.

Frequently asked questions

What is a standard stainless steel mesh size?

There isn’t a single standard size. Common industrial cloth runs from about 2 to 635 mesh. Everyday sizes include 4 and 8 mesh for hardware cloth, 18×16 for insect screen, 40–100 mesh for strainers and 200–400 mesh for fine filtration and sieving. Each mesh count can also come in several wire diameters.

What does 100 mesh mean?

It means 100 openings per linear inch. With the common 0.0045 in wire, that gives an opening of 0.0055 in (about 140 µm) and about 30% open area. A No. 100 test sieve has a slightly larger 150 µm opening.

What is the opening of 12 mesh stainless steel screen?

With 0.023 in wire, 12 mesh has an opening of about 0.060 in (1.53 mm) and about 52% open area. A heavier or lighter wire changes the opening, so check the wire diameter as well as the count.

What is the smallest mesh size available?

Standard square-opening cloth commonly goes down to 500–635 mesh, with openings of about 25 and 20 µm. For finer filtration, manufacturers use Dutch weaves and other filter media rated in microns rather than mesh.

Is a higher mesh number finer or coarser?

Finer. A higher count puts more wires in each inch, so the openings are smaller. A 200 mesh screen has much smaller openings than a 20 mesh screen, usually with lower flow and thinner wire.

Is 304 stainless steel mesh magnetic?

It can be slightly. Annealed 304 is essentially non-magnetic, but the cold drawing used to make wire can make it weakly magnetic. A pull toward a magnet doesn’t mean the mesh is fake or low grade. The guide to stainless steel and magnets explains why. Only a chemical test confirms the grade.

Is there a difference between screen and mesh?

In practice the words overlap. “Screen” usually refers to the finished job, such as an insect screen or a sieve, and “mesh” to the wire material and its count. “Wire cloth” is the trade term for the woven product. All of them can be specified with the same mesh count and wire diameter.

Last updated: November 2026. Opening, open area and weight figures are calculated from nominal mesh and wire sizes, and sieve openings follow the ASTM E11 series. Actual cloth varies with the maker and tolerances, so confirm critical sizes against the current standard or the supplier’s data sheet. Application sizes are typical starting points.

Sponsored

Related posts